TROUBLESHOOTING
(HOW TO CORRECT THE SETTINGS FOR THE UNIVERSITY OF IOWA GPS SYSTEM)
Model: Z-Xtreme
GPS Mode: RTK
- Arrow left to the "Files" tab at the top of the screen.
2) Check receiver settings: - From the Settings screen, hit "Receiver settings" box in the lower right corner.
Format for RTK: DBEN
Serial Port (Data Collector): COM 1
Serial Port (GPS Receiver): A
Baudrate: 9600
Parity: None
-Tap the "Change" box if any of the settings need to be set
3) Check Base Radio settings: - Tap on the "Base Radio" tab at the top of the GPS
Receiver Settings screen.
Radio Modem: Pac Crest
Baudrate: 9600
Parity: None
Serial: B
Channel: 0
Sensitivity: Low
- Tap the "Configure" box beside any settings which need to be set to change settings.
4) Check Mode of Measurement: - From the main menu select "Job", then "Settings" from the right hand side.
Acceptance Mode: Fine
Store GPS Raw: + variances
Epochs to Average on Accept: 10
The box for "Use criteria to auto accept
Data Points" should be shaded
5) Check Projection settings: -From the same settings screen, tap the "Projection" tab at the top of the screen.
-The settings should be:
Horizontal: Localization: Control Points
Vertical: Localization
6) Check Units of Measurement: From the same settings screen, arrow left and tap on the "Units" tab at the top of the screen.
-The settings should be:
Units for Distance: US Survey Feet
Units for Angles: Degrees
Display Directions as: Azimuth
Azimuth Type: North Azimuth
The Ranger unit is now programmed with the proper settings if it reads as above. If problems continue, refer to other topics of the "Troubleshooting" section of the web page.